Flat steel mass
Estimate uncoated flat steel mass using developed width.
Calculation method
Developed width × length × thickness in mm × 7.85 (steel density 7,850 kg/m³).
Planning estimate only. Excludes allowances, complex geometry, coatings, installation details and engineering design. Verify inputs and final quantities with your supplier.
Convert confirmed coil yield to tonnes
If the supplier confirms the yield for the exact coil, divide the total ordered lineal metres by that coil’s metres per tonne. For example, 600 sheets of 3.6 m total 2,160 lineal metres. At an illustrative confirmed yield of 544 m/t, 2,160 ÷ 544 ≈ 3.971 t before scrap and allowance.
Use the supplied coil’s measured mass and length or a current supplier yield. Feed width and installed effective cover are different. Do not use the latter to estimate coil mass, or carry one coating’s yield over to another specification.